Gillpatch® 6006 System is a fiberglass reinforced polyester laminate with a pressure sensitive adhesive applied to the back side.
Gillpatch® 6006 is designed as a patch for repairing holes and tears in cargo compartment liners.
Gillpatch® 6006 is approved for use in Class B and E cargo compartment as defined in FAR 25.857.
Thickness, inch (mm) | 0.026 (0.660) |
Size, inch x inch (mm x mm) | 4.5 x 4.5 (114 x 114), 6 x 6 (152 x 152), 9 x 9 (229 x 229), and 12 x 12 (305 x 305) |
Sheet Stock, inch x inch (mm x mm) | Maximum 36 x 72 (914 x 1,829) |
Adhesive: Pressure sensitive adhesive
Resin: Polyester resin
Reinforcement: Woven fiberglass cloth
TGC Product No. | Difference |
---|---|
Gillpatch® III 6306 | Fiberglass/phenolic laminate with adhesive on the back side. Superior impact strength comparing to 6006 and 1367P. |
The following tests are run in accordance with ASTM standard methods.
TGC Part Number | 60061 | |
---|---|---|
Weight, psf (kg/m2) | 0.60 (2.93) | |
Flexural Strength2, ksi (Mpa) | 18 (124) | |
After 2 hr boiling | 12 (83) | |
Flexural Modulus2, msi (Gpa) | 0.8 (5.52) | |
After 2 hr boiling | 0.5 (3.4) | |
Tensile Strength3, ksi (Mpa) | 38 (262) | |
After 2 hr boiling | 30 (207) | |
Tensile Modulus3, msi (Gpa) | 0.8 (5.52) | |
After 2 hr boiling | 0.5 (3.4) | |
Compressive Strength4, ksi (Mpa) | 9 (62) | |
After 2 hr boiling | 6 (41) | |
Bearing Strength5, ksi (Mpa) | 12 (83) | |
Shearing Strength6, ksi (Mpa) | 18 (124) | |
Resin Content, % | 38 | |
Barcol Hardness7 | 30 | |
Water absorption8, % | 2.5 | |
Flammability | Meet FAR 25.853 App F Part I (a)(1)(ii) |
1Test on a 0.015 laminate without adhesive on the back side.
2ASTM D790, warp direction
3ASTM D638, warp direction
4ASTM D695
5ASTM D953
6ASTM D732
7Barcol is a relative hardness measurement without unit
8ASTM D570
Figures shown reflect typical values and should not be used as design specifications.
This product is safe to use and apply when recommended precautions are followed. Before using this product, read and understand the Safety Data Sheet (SDS), which provides information on health, physical and environmental hazards, handling precautions and first aid recommendations. For industrial use only. Keep away from children. Additional information can be found at: www.thegillcorp.com. For sales and ordering information call 1-626-443-6094.
All recommendations, statements, values and technical data herein are based on tests The Gill Corporation believes to be reliable and correct, but accuracy and completeness of said tests are not guaranteed and are not to be construed as a warranty, either expressed or implied. Users shall rely on their own information and tests to determine suitability of the product for the intended use and assume all risks and liability resulting from their use of the product. The Gill Corporation’s sole responsibility shall be to replace that portion of the product that proves to be defective. The Gill Corporation will not be liable to the buyer or any third person for any injury, loss or damage directly or indirectly resulting from use of, or inability to use, the product. Recommendations or statements not contained in a written agreement signed by an officer of The Gill Corporation shall not be binding upon The Gill Corporation. Alcopan™, Alphex®, CGH® Dura-Core®, Gillfab®, Gillfloor®, Gilliner®, Gillite®, Gillfists®, GillVANA®, Higrid®, Hushgrid®, PAA-Core®, Plygrid®, Shapegrid®, Strikegrid®, Trussgrid® are registered trademarks of The Gill Corporation.